power.jpg (5308 bytes)                         

Welcome to Martek Power Abbott


W Series
12 - 280 Watt Single Output Power Supply

WW Series
1.8 - 240 Watt Dual Output Power Supply

w_sm.jpg (9038 bytes)

Download Data sheet in pdf

Features
High reliability linear, MTBF 214,600 hours.
Military operating temp range: -55°C to +100°C.
249 standard models.
Meets MIL-STD-461A, MIL-STD-810C and MIL-S-901C.

 

Specifications
Input: 105-125 Vac, 380-420 Hz, single phase.
Output: 5-100 Vdc (single output).
±3, ±30 Vdc (dual output).
Efficiency: 25-60%.
Line Regulation: Single output within 0.1%, dual output within 0.2% or 10 mV (whichever is greater) for change from low line to high line with load constant.
Load Regulation: Single output within 0.1%, dual output within 0.2% or 20 mV (whichever is greater) for change from no load to full load with line constant.
Auxiliary Output Tracking: WW Models. The negative output will track the positive output within 1% or 100 mV (whichever is greater) for all rated conditions.
Pard (Noise and Ripple): 0.02% or 5 mV rms (whichever is greater), 25 mV P-P at 25 MHz bandwidth.
Isolation Voltage: 750 Vdc, input to output; 750 Vdc, input to case; 200 Vdc, output to case.
Insulation Resistance: 50 Mohms between input and output, input and case, output and case, when measured at 50 Vdc.
Polarity: Inputs and outputs are isolated. Either positive or negative side of output may be grounded.
Temperature Range: Operating: -55°C to +100°C maximum, at center of the baseplate. Storage: -65°C to +125°C, ambient.
Temperature Coefficient: 0.03% / °C maximum.
Input Transient Protection: Unit will withstand 180 Vac for 0.1 second, in accordance with MIL-STD-704A.
Load Transient Recovery: Single output: output voltage returns to regulation limits within 100 microsecond for auxiliary outputs after 50% change in load current for units supplying 10 A or less and 200 microseconds for units supplying more than 10 A. Dual output: output voltage returns to regulation limits within 200 microseconds after 50% change in load current
Turn-on/Turn-off Overshoot: Single output 0.2% or 20 mV (whichever is greater), dual output 0.2% or 30 mV (whichever is greater) from nominal voltage set point.
Short Circuit Protection: Completely protected against a short circuit of any duration. Output automatically restores to normal when overload is removed.
Overvoltage Protection: External modules are available for use with all models and internal OVP circuit is available for selected models. Please see -1 option.
EMI: Units were designed and built to minimize EMI/EMC emissions, and comply with the requirements of MIL-STD-461A by virtue of their topology, construction and enclosure.
Reliability: MTBF is calculated per MIL-HDBK-217D at 50°C baseplate temperature with maximum operating input voltage and maximum rated output power. The MTBF for W5D10 at ground benign environment is 214,600 hours.
Environment: Encapsulated and hermetically sealed to meet the environmental requirements of MIL-STD-810C.
Connectors: Standard unit is provided with an input solder pin header and an output "hermetic seal" stud-type connector.
Weight (Lbs.): 1.9 - 8.9
Size (inches): See Selection Chart

Single-Output Click here for a larger version of this graphic.

Dual-Output Dual-Output Case Diagram

Model Numbering System
Model Series Nominal Output Voltage Header Type Options Maximum Output Current
W* 9 D L - 10
*W is for single output, WW is for dual output.

 

SELECTION CHART for listing of popular models, case sizes, pin outs and input currents.

 

Options
A Option: Special Connectors. A military-type hermetically sealed connector is provided in place of our standard input header. To order, replace the "D" in the model with "A".
E Option: Severe Shock, Acceleration and Vibration. Enables all units to withstand 60 g's shock, 50 g's acceleration and 30g's vibration. To order, add "E" after "D" in the model number.
L Option: Remote Turn On/Off. Provides isolated terminals to turn output on/off with TTL logic signal. To order, add "L" after "D" in the model number.
R Option: An adjustment potentiometer can be remotely located to adjust the output voltage. To order, add "R" after the "D" in the model number.
Y Option: Remote Error Sensing. Regulator monitors the output voltage directly at the load using extra "sensing" leads and compensates for a dc voltage drop of up to .3 volts in the load lead. This option is inluded at no extra charge when Option A is ordered. To order, add "Y" after "D" in the model number.
-ER Option: Provides increased reliability by using higher levels of military grade components. To order, add "-ER" after the model number.
-1 Option: Internal Overvoltage Protection. Provides a crowbar internal OVP. Input must be recycled to restore output. May inccrease case size. To order, add "-1" to the end of the model number.