SN Series (SN180D)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Features |
| High density 2 W/in³ 180-watt inverter |
| Military operating temp range: -55°C to +100°C. |
| 400 Hz, 800 Hz and 1600 Hz output frequency |
| Specifications | ||||
| Input: | 24 - 30 Vdc, single phase. (see option H). | |||
| Output: | 25.4 - 28.6 Vac, 108-122 Vac | |||
| Efficiency: | 50% typical at 27 Vdc input and full resistive load (no options). | |||
| Line Regulation: | Within 0.5% for full input change 24 Vdc to 30 Vdc with load constant. | |||
| Load Regulation: | Within 1.0% for load change of one half to full load with line constant. | |||
| Wave Form: | Sinusoidal with a 4% maximum harmonic distortion into a resistive load. | |||
| Frequency Stability: | ±1% drift with time (within the first 8 hours after 30 seconds warm-up). | |||
| Frequency Accuracy: | ±0.5% is initial setting tolerance. | |||
| Load Power Factor: | Derate linearly from 100% rated power at unity to 70% rated power at 0.7 power factor lagging or leading. | |||
| Isolation Voltage: | 750 Vdc, input to output; 200 Vdc, input to case; 750 Vdc, output to case. | |||
| Insulation Resistance: | 50 Mohms between input and output, input and case, output and case, when measured at 50 Vdc. | |||
| Temperature Range: | Operating: -55°C to +100°C maximum, at center of the baseplate. Storage: -65°C to +125°C, ambient. | |||
| Temperature Coefficient: | 0.06% / °C from -55°C to +100°C, voltage change, frequency change, 1% maximum. | |||
| Input Transient Protection: | Unit will withstand 80 Vdc for 0.1 second, in accordance with MIL-STD-704A. | |||
| Load Transient Response: | Output voltage returns to regulation limits within 5 cycles for a load change of no load to full load. | |||
| Load Transient Overshoot: | 10% maximum from nominal voltage set point. | |||
| Short Circuit Protection: | Completely protected against a short circuit of any duration. Unit must be recycled to restore output to normal when overload is removed. | |||
| EMI: | Units were designed and built to minimize EMI/EMC emissions, and comply with the requirements of MIL-STD-461A by virtue of their topology, construction and enclosure. | |||
| Reliability: | MTBF is calculated per MIL-HDBK-217D at 50°C baseplate temperature with maximum operating input voltage and maximum rated output power. The MTBF at ground benign environment is 156,366 hours and 15,722 hours for air inhabited transport environments. With -ER option MTBF at ground benign is 907,070 hours and 93,030 for air inhabited transport environments. Consult factory for other model and environment information. | |||
| Environment: | Encapsulated and hermetically sealed to meet the environmental requirements of MIL-STD-810C. | |||
| Connectors: | Standard unit is provided with an input solder 4 pin header. (See option -A for other connectors.) | |||
| Weight (Lbs.): | Maximum 5.5 lbs. not including options. | |||
| Size (inches): | A |
|||
| 6.0 x 6.0 x 2.50 | ||||

| Model Numbering System | |||||||
| Model Series | Nominal Output Power | Header Type | Options | Output Voltage |
Frequency Hz |
||
| SN | 180 | D | - | 27A | - | 400 | |
| Output Voltage: 27 or 115. | |||||||
| Frequency: 400,800 or 1600. | |||||||
| Options | |
| A Option: | Special Connectors. A military-type hermetically sealed connector is provided in place of our standard input header. To order, replace the "D" in the model with "A". |
| E Option: | Severe Shock, Acceleration and Vibration. Enables all units to withstand 60 g's shock, 50 g's acceleration and 30g's vibration. To order, add "E" after "D" in the model number. |
| H Option: | Wide Input Voltage. Recenters the input voltage to provide alternate inputs from 18 Vdc to 32 Vdc. To order, add "H" after "D" in the model number and specify input voltage range in parentheses after the entire model number. |
| L Option: | Remote Turn On/Off. Provides isolated terminals to turn output on/off with TTL logic signal. To order, add "L" after "D" in the model number. |
| R Option: | Remote Output Adjustment. An adjustment potentiometer can be remotely located to adjust the output voltage. To order, add "R" after the "D" in the model number. |
| -ER Option: | Provides increased reliability by using higher levels of military grade components. To order, add "-ER" after the model number. |
| -4 Option: | Frequency Adjustment. Enables output frequency to be adjusted ±5% by means of an external potentiometer. To order, add "-4" at the end of the entire model number. |
| OT Option: | Option OT turns off input power when conduction surfaces exceed safe limits. To order, add "OT" after the "D" in the model number. |