| Specifications |
| Input: |
24 - 30 Vdc, single phase. |
| Output: |
25.4 - 28.6 Vac, 108-122 Vac |
| Efficiency: |
30 - 50% typical at 27 Vdc
input and full load. |
| Line
Regulation: |
Within 0.4% for full input
change 24 Vdc to 30 Vdc with load constant. |
| Load
Regulation: |
Within 1.0% for load change
of 50% to full load with line constant. |
| Wave Form: |
Sinusoidal with a 4% maximum
harmonic distortion into a resistive load. |
| Frequency
Stability: |
±1% drift with time (within
the first 8 hours after 30 seconds warm-up). |
| Frequency
Accuracy: |
±0.5% is initial setting
tolerance. |
| Load Power
Factor: |
Full rated output VA from
unity to 0.7 power factor lagging or leading. |
| Isolation
Voltage: |
750 Vdc, input to output;
200 Vdc, input to case; 200 Vdc, output to case. |
| Insulation
Resistance: |
50 Mohms between input and
output, input and case, output and case, when measured at 50 Vdc. |
| Polarity: |
Inputs and outputs are
isolated, either positive or negative side may be grounded. |
| Temperature
Range: |
Operating: -55°C to +100°C
maximum, at center of the baseplate. Storage: -55°C to +125°C, ambient. |
| Temperature
Coefficient: |
0.02% / °C from
-20°C to +71°C baseplate temperature, 0.06% / °C over entire range, voltage change. |
| Input Transient
Protection: |
Unit will withstand 80 Vdc
for 0.1 second, in accordance with MIL-STD-704A. |
| Short Circuit
Protection: |
Completely protected against
a short circuit of any duration. Unit must be recycled to restore output to normal when
overload is removed. |
| EMI: |
Units were designed and
built to minimize EMI/EMC emissions, and comply with the requirements of MIL-STD-461A by
virtue of their topology, construction and enclosure. |
| Reliability: |
MTBF is calculated per
MIL-HDBK-217D at 50°C baseplate temperature with maximum operating input voltage and
maximum rated output power. The MTBF at ground benign environment is 340,600 hours and
31,300 hours for air inhabited transport environments. |
| Environment: |
Encapsulated and
hermetically sealed to meet the environmental requirements of MIL-STD-810C and
MIL-E-5400P. |
| Connectors: |
Standard unit is provided
with an input solder 4 pin header. (See option -A for other connectors.) |
| Weight (Lbs.): |
1.6 |
| Size (inches): |
2.25 x 2.75 x 3.25 |
| Options |
| A Option: |
Special Connectors. A
military-type hermetically sealed connector is provided in place of our standard input
header. To order, replace the "D" in the model number with "A". |
| B Option: |
Alternate Head Location. The
standard multiple pin header is relocated to the bottom (baseplate) surface. To order
replace the "D" in the model number with "B". |
| E Option: |
Severe Shock, Acceleration
and Vibration. Enables all units to withstand 60 g's shock, 50 g's acceleration and 30g's
vibration. To order, add "E" after "D" in the model number. |
| H Option: |
Wide Input Voltage.
Recenters the input voltage to provide alternate inputs from 20 Vdc to 32 Vdc. To order,
add "H" after "D" in the model number and specify input voltage range
in parentheses after the entire model number. |
| R Option: |
Remote Output Adjustment. An
adjustment potentiometer can be remotely located to adjust the output voltage. To order,
add "R" after the "D" in the model number. |