power.jpg (5308 bytes)                            

Welcome to Abbott Electronics.


MH Series (MH500S)
500 Watt Single Output Power Supply  

                 Click here for a larger version of this image.

Features
500 watt switching 100 KHz power supply.
High efficiency, 65% minimum.
Standard soft-start, overvoltage protection and short circuit protection.

 

Specifications
Input: 103.5-126.5 Vac, 47-440 Hz, single phase. For 207-253 Vac input, add "(230)" at the end of the model number.
Efficiency: 65% minimum.
Line Regulation: 25 mV or withing 0.2%, whichever is greater, for input change of 103.5 to 126.5 Vac with load constant.
Load Regulation: 25 mV or 0.2%, whichever is greater for change from no load to full load with line constant.
Pard (Noise and Ripple): 50 mV rms, 100 mV P-P maximum at 25 MHz bandwidth.
Isolation Voltage: 500 Vdc, input to output; 500 Vdc, input to case; 100 Vdc, output to case.
Insulation Resistance: 50 Mohms between input and output, input and case, output and case, when measured at 50 Vdc.
Polarity: Inputs and outputs are isolated. Either positive or negative side of output may be grounded.
Temperature Range: Operating: 0°C to +71°C maximum, at center of the mounting. Storage: -55°C to +85°C, ambient.
Temperature Coefficient: 0.03% / °C maximum over entire temp range.
Input Transient Protection: Unit will provide normal regulated output and withstand 180 Vac for 0.1 second, in accordance with MIL-STD-704A.
Load Transient Recovery: Output voltage returns to regulation limits within 300 microseconds after 50% change in load current.
Holdup time: 20ms after nominal input is lost at full load.
Short Circuit Protection: Completely protected against a short circuit of any duration. Output automatically restores to normal when overload is removed.
Overvoltage Protection: A non-crowbar type OVP. Input must be recycled to restore output.
Remote Sensing: Regulator monitors voltage directly at the load using extra "sensing" leads and compensates for a dc voltage drop up to .3 volt in the load leads.
EMI: Units were designed and tested to the requirement of MIL-STD-461B, Class A1B, for generation of and susceptibility to radiated and conducted interference. For further details and reports, consult your nearest sales office.
Reliability: MTBF is calculated per MIL-HDBK-217D at 50°C baseplate temperature with maximum operating input voltage and maximum rated output power. The MTBF for MH500S at ground benign environment is 54,530 hours.
Environment: Encapsulated and hermetically sealed to meet the environmental requirements of MIL-STD-810C, MIL-S-901C, and MIL-E-5400P, Class 2, including altitude (to 70,000 feet), vibration, shock, acceleration, sand, dust, humidity, saltspray, fungus, explosion, etc.
Connectors: Standard unit is provided with an input solder pin header and an output "hermetic seal" stud-type connector.


Single Output
clear_dot.gif (43 bytes) Output Voltage Range Output Current (Amps) Weight (lb.) Size (inches)
MH500S/5-DE 4.75-5.25 100 15 7 x 10 x 3.5
MH500S/12-DE 11.40-12.60 41.67 15 7 x 10 x 3.5
MH500S/15-DE 14.25-15.75 33.33 15 7 x 10 x 3.5
MH500S/24-DE 22.80-25.20 20.83 15 7 x 10 x 3.5
MH500S/28-DE 26.60-29.40 17.86 15 7 x 10 x 3.5

Case diagram.

Model Numbering System
Model Series Total Output Power Number of Outputs clear_dot.gif (43 bytes) Main Output Voltage clear_dot.gif (43 bytes) Header Type clear_dot.gif (43 bytes) Encap-
sulation (Standard)
clear_dot.gif (43 bytes) Options
MH 500 S / 12 - D - E - R

 

Options
A Option: Special Connectors. A military-type hermetically sealed connector is provided in place of our standard input header. To order, replace the "D" in the model with "A".
H Option: Wide Input Voltage. Unites will operate either from 115 Vac±15%. To order, add an "H" after the "E" in the model number.
L Option: Remote Turn On/Off. Provides isolated terminals to turn output on/off with TTL logic signal. To order, add "L" after "E" in the model number.
R Option: Remote Output Adjustment. An adjustment potentiometer can be remotely located to adjust the output voltage. To order, add "R" after "E" in the model number.
T Option: Wider Operating Temperature. -20°C to +71°C. To order, add "T" after "E" in the model number.
-ER Option: Provides increased reliability by using higher levels of military grade components.
-3 Option: WYE Input. Changes input to 3-phase, 4-wire "WYE". To order, add "-3" to the end of the model number.
-6 Option: Three Phase Delta Input. Changes input to 3-Phase Delta. To order, add "-6" to the end of the model number.
-8 Option: Variable Input. Allows input to be either 115 Vac or 230 Vac, selectable by input pin wiring, 47 - 440 Hz. To order, add "-8" to the end of the model number.