MH Series (MH500S)
500 Watt Single Output Power Supply

| Features |
| 500 watt switching 100 KHz power supply. |
| High efficiency, 65% minimum. |
| Standard soft-start, overvoltage
protection and short circuit protection. |
| Specifications |
| Input: |
103.5-126.5 Vac, 47-440 Hz,
single phase. For 207-253 Vac input, add "(230)" at the end of the model number. |
| Efficiency: |
65% minimum. |
| Line
Regulation: |
25 mV or withing 0.2%,
whichever is greater, for input change of 103.5 to 126.5 Vac with load constant. |
| Load
Regulation: |
25 mV or 0.2%, whichever is
greater for change from no load to full load with line constant. |
| Pard (Noise and
Ripple): |
50 mV rms, 100 mV P-P
maximum at 25 MHz bandwidth. |
| Isolation
Voltage: |
500 Vdc, input to output;
500 Vdc, input to case; 100 Vdc, output to case. |
| Insulation
Resistance: |
50 Mohms between input and
output, input and case, output and case, when measured at 50 Vdc. |
| Polarity: |
Inputs and outputs are
isolated. Either positive or negative side of output may be grounded. |
| Temperature
Range: |
Operating: 0°C to +71°C
maximum, at center of the mounting. Storage: -55°C to +85°C, ambient. |
| Temperature
Coefficient: |
0.03% / °C maximum over
entire temp range. |
| Input Transient
Protection: |
Unit will provide normal
regulated output and withstand 180 Vac for 0.1 second, in accordance with MIL-STD-704A. |
| Load Transient
Recovery: |
Output voltage returns to
regulation limits within 300 microseconds after 50% change in load current. |
| Holdup time: |
20ms after nominal input is
lost at full load. |
| Short Circuit
Protection: |
Completely protected against
a short circuit of any duration. Output automatically restores to normal when overload is
removed. |
| Overvoltage
Protection: |
A non-crowbar type OVP.
Input must be recycled to restore output. |
| Remote Sensing: |
Regulator monitors voltage
directly at the load using extra "sensing" leads and compensates for a dc
voltage drop up to .3 volt in the load leads. |
| EMI: |
Units were designed and
tested to the requirement of MIL-STD-461B, Class A1B, for generation of and susceptibility
to radiated and conducted interference. For further details and reports, consult your
nearest sales office. |
| Reliability: |
MTBF is calculated per
MIL-HDBK-217D at 50°C baseplate temperature with maximum operating input voltage and
maximum rated output power. The MTBF for MH500S at ground benign environment is 54,530
hours. |
| Environment: |
Encapsulated and
hermetically sealed to meet the environmental requirements of MIL-STD-810C, MIL-S-901C,
and MIL-E-5400P, Class 2, including altitude (to 70,000 feet), vibration, shock,
acceleration, sand, dust, humidity, saltspray, fungus, explosion, etc. |
| Connectors: |
Standard unit is provided
with an input solder pin header and an output "hermetic seal" stud-type
connector. |
| Single Output |
 |
Output Voltage
Range |
Output Current
(Amps) |
Weight (lb.) |
Size (inches) |
| MH500S/5-DE |
4.75-5.25 |
100 |
15 |
7 x 10 x 3.5 |
| MH500S/12-DE |
11.40-12.60 |
41.67 |
15 |
7 x 10 x 3.5 |
| MH500S/15-DE |
14.25-15.75 |
33.33 |
15 |
7 x 10 x 3.5 |
| MH500S/24-DE |
22.80-25.20 |
20.83 |
15 |
7 x 10 x 3.5 |
| MH500S/28-DE |
26.60-29.40 |
17.86 |
15 |
7 x 10 x 3.5 |

| Model Numbering System |
| Model Series |
Total Output
Power |
Number of
Outputs |
 |
Main Output
Voltage |
 |
Header Type |
 |
Encap-
sulation (Standard) |
 |
Options |
| MH |
500 |
S |
/ |
12 |
- |
D |
- |
E |
- |
R |
| Options |
| A Option: |
Special Connectors. A
military-type hermetically sealed connector is provided in place of our standard input
header. To order, replace the "D" in the model with "A". |
| H Option: |
Wide Input Voltage. Unites
will operate either from 115 Vac±15%. To order, add an "H" after the
"E" in the model number. |
| L Option: |
Remote Turn On/Off. Provides
isolated terminals to turn output on/off with TTL logic signal. To order, add
"L" after "E" in the model number. |
| R Option: |
Remote Output Adjustment. An
adjustment potentiometer can be remotely located to adjust the output voltage. To order,
add "R" after "E" in the model number. |
| T Option: |
Wider Operating Temperature.
-20°C to +71°C. To order, add "T" after "E" in the model number. |
| -ER Option: |
Provides increased
reliability by using higher levels of military grade components. |
| -3 Option: |
WYE Input. Changes input to
3-phase, 4-wire "WYE". To order, add "-3" to the end of the model
number. |
| -6 Option: |
Three Phase Delta Input.
Changes input to 3-Phase Delta. To order, add "-6" to the end of the model
number. |
| -8 Option: |
Variable Input. Allows input
to be either 115 Vac or 230 Vac, selectable by input pin wiring, 47 - 440 Hz. To order,
add "-8" to the end of the model number. |
|