AW Series (AW100S)
100 Watt Single Output Power Supplies

Specifications
Input: 103-127 Vac, 47-440 Hz, single phase. 90-160 Vdc.
Efficiency: 65% minimum. Typically (nominal input, full load, room ambient) 70-80%.  50-60% typical for 2.0 and 3.3 Vdc output units.
Line Regulation: 10 mV or 0.1%, whichever is greater, over entire input range with load held constant.
Load Regulation: 10 mV or 0.1%, whichever is greater from no load to full load with line held constant.
Pard (Noise and Ripple): 25 mV rms, 100 mV P-P for 5 Vdc output and 50 mV rms, 200 mV P-P for other voltages; measured at 25 MHz bandwidth over temperature range.
Isolation Voltage: 700 Vdc, input to output; 500 Vdc, input to case; 200 Vdc, output to case.
Insulation Resistance: 50 Mohms between input and output, input and case, output and case, when measured at 50 Vdc.
Temperature Range: Operating: -55°C to +100°C maximum, at center of the baseplate. Storage: -55°C to +125°C, ambient.
Temperature Coefficient: 0.01% / °C maximum over entire temp range.
Input Transient Protection: Unit will provide normal regulated output and withstand 180 Vac for 0.1 second, in accordance with MIL-STD-704A.
Load Transient Recovery: Output voltage returns to regulation limits within 0.5 milliseconds after 50% change in load current.
Load Transient Overshoot: 0.5 V from nominal voltage set point.
Short Circuit Protection: Completely protected against a short circuit of any duration. Output automatically restores to normal when overload is removed.
Remote Sensing: Compensates for up to 0.5 volt drop in leads.  Sense pins must be tied local (at connector) or remote (at load) for proper operation.
Remote Inhibit: Provides for remote turn on / off with TTL logic signal. Application of TTL Signal (logic 1) will inhibit the outputs.   10mA required current (@5 Vdc).
EMI: Units, when tested in accordance with MIL-STD-462, meet the majority of the requirements of MIL-STD-461C for conducted and radiated, emission and susceptibility, for Class A1, A2 and A3 equipment for input power leads. For further details regarding levels and extent of compliance in each class, consult your nearest sales office.
Parallelability: The 100 and 200 watt units allow for multiple unit current sharing without the need for external components, via a single pin connection on each unit.
Switching Frequency: 160 to 200 kHz fixed.
Environment: Units meet MIL-STD-810C, altitude, shock acceleration, vibration and MIL-S-901C high-impact shock requirements. Please consult factory for more information.
Hook-Up: Via D-Subminiature connectors, M24308/24 type.


Single Output
clear_dot.gif (43 bytes) Nominal Output Voltage Output Current (Amps) Weight (oz.) Size (inches)
A B C
AW100S/2-A 2 20.00 21 3.75 x 5.25 x 0.85
AW100S/3.3-A 3.3 20.00 21 3.75 x 5.25 x 0.85
AW100S/5-A 5 20.00 21 3.75 x 5.25 x 0.85
AW100S/5.2-A 5.2 19.23 21 3.75 x 5.25 x 0.85
AW100S/12-A 12 8.33 21 3.75 x 5.25 x 0.85
AW100S/15-A 15 6.66 21 3.75 x 5.25 x 0.85
AW100S/24-A 24 4.16 21 3.75 x 5.25 x 0.85
AW100S/28-A 28 3.57 21 3.75 x 5.25 x 0.85
Set point accuracy: 50mV or 0.5% whichever is greater

Click here for a larger version of this graphic.

Model Numbering System
Model Series Total Output Power Number of Outputs clear_dot.gif (43 bytes) Main Output Voltage clear_dot.gif (43 bytes) Header Type clear_dot.gif (43 bytes) Options
AW 100 S / 12 - A - 883

 

Options
-883 Option: Unit undergoes environmental screening based upon the parameters outlined in MIL-STD-883 and NAVMAT 4855-1. The screening consists of :
1.) Stablization Bake: +125oC for 24 hours per MIl-STD-883, M1108 Condition B.
2.) Temperature Cycling (non-operational): 10 cycles min., at -55oC to +125oC, 36 minute transition with 1 hour dwell at each temperature extreme. Procedure reference MIl-STD-883, M1010, Condition B and NAVMAT P4855-1.
3.) Long Term Operational Burn In: 160 hours of powered operation under load. Modules are continuously cycled from +85oC to thermal shut down point (+105oC) during the 160 hours.
Environmental Stress Screening: Environmental Stress Screening (ESS) including random vibration and thermal cycling per the NAVMAT guidelines is available.  Consult factory for details.
Ruggedized: COTS readily available components are utilized. Contact factory for details.
-ER Option: Provides increased reliability by using higher levels of military grade components.  (Not recommended for new designs.)