AM Series (AM50S/AM50T)
50 Watt Single & Triple Output Power Supply

Features
Customer selectable, Multi-Inputs.
Wireless submodular construction for high reliability.
Short circuit protection standard.

 

Specifications
Input: 90-130 Vac, 47-440 Hz, single phase or 3 phase (Delta, WYE)
180 to 260 Vac, 47-440 Hz, single phase or 3 phase (Delta); 200-300 Vdc. "S" version input ranges: 100- 200 Vdc.
See Input Connection/Pin No.
Efficiency: 65% minimum. Typically (full load, room ambient) 75%
Line Regulation: Single or main: 0.1% or 10 mV, whichever is greater. Auxiliaries: for ±15V, 100mV maximum; for ±12V, 60mV maximum.
Load Regulation: Single or main: 0.1% or 10 mV, whichever is greater. Auxiliaries: 150mV maximum.
Pard (Noise and Ripple): 25mV rms, 100mV P-P for 5 Vdc output and 50 mV rms, 200 mV P-P for other voltages; measured at 25 MHz bandwidth over temperature range.
Isolation Voltage: 1000 Vdc, input to output; 1000 Vdc, input to case; 200 Vdc, output to case.
Insulation Resistance: 50 Mohms between input and output, input and case, output and case, when measured at 50 Vdc.
Temperature Range: Operating: -55ºC to +100ºC maximum, at center of the baseplate. Storage: -55ºC to +125ºC, ambient.
Temperature Coefficient: 0.01% / °C maximum over entire temp range.
Input Transient Protection: Unit will not be damaged or exhibit degradation of performance when subjected to input transients in accordance with MIL-STD-704A, MIL-STD-704D and MIL-STD-1399, as applicable to corresponding input configurations.
Load Transient Recovery: Output voltage returns to regulation limits within 0.5 milliseconds after 50% change in load current.
Load Transient Overshoot: 0.5V from nominal voltage set point.
Short Circuit Protection: Completely protected against a short circuit of any duration. Output automatically restores to normal when overload is removed.
Current Limiting: Standard.
Remote Sensing: Regulator monitors voltage directly at the load using extra "sensing" leads and compensates for a dc voltage drop up to .5 volt in the load leads. (Single and main output only.)  Sense pins must be tied local (at connector) or remote (at load) for proper operation.
Preload Requirements: For Triple output only. A one amp minimum load is required on the main for full load capabilities on the auxiliaries.
Remote Inhibit: Provides for remote turn on/off with TTL logic signal. Application of TTL Signal (logic 1) will inhibit the outputs.   10mA required current (@5 Vdc).
EMI: Units were designed and tested to the requirement of MIL-STD-461B, Class A1B, for generation of and susceptibility to radiated and conducted interference. For further details and reports, consult your nearest sales office.
Switching Frequency: 160 to 200 kHz fixed.
Reliability: MTBF is calculated per MIL-HDBK-217E at 50ºC baseplate temperature with maximum operating input voltage and maximum rated output power. The MTBF for AM50S at ground benign environment is 160,300 hours. With -ER option, MTBF was calculated to be 240,000 hours at ground benign and 25,000 for naval sheltered.
Environment: Units meet MIL-STD-810D, altitude, shock acceleration, vibration and MIL-S-901C high-impact shock requirements. Please consult factory for more information.
Hook Up: Via D-Subminiature connectors, M24308/24 type.


Single Output
clear_dot.gif (43 bytes) Nominal
Output
Voltage
Output Current (Amps) Weight (Oz.) Size (inches)
AM50S/5-A 5 10.0 12 3.25 x 4.25 x .85
AM50S/5.2-A 5.2 9.62 12 3.25 x 4.25 x .85
AM50S/12-A 12 4.17 12 3.25 x 4.25 x .85
AM50S/15-A 15 3.33 12 3.25 x 4.25 x .85
AM50S/24-A 24 2.08 12 3.25 x 4.25 x .85
AM50S/28-A 28 1.79 12 3.25 x 4.25 x .85
Set point accuracy: 50mV or 0.5% whichever is greater

 

Triple Output
Output
Voltage
(main/aux)
Output
Current
(m/aux)
Weight
(Oz.)
Size (inches)
AM50T/5/12-A 5 / ±12 7.0/0.63 15 3.50 x 4.50 x .85
AM50T/5/15-A 5 / ±15 7.0/0.5 15 3.50 x 4.50 x .85

Set point accuracy:

±25mV Main
±500mV Aux

Input Connection - AM50S
Input Connection Pin No.
100-300 Vdc or 230 Vac 1Ø 1 (+)(H), 9 (-)(N)
115 Vac 1Ø 47-440 Hz 1 (H), 2 (N)
115/230 Vac 3Ø 47-440 Hz 1, 9, 10
115 Vac 3ØY 47-440 Hz 1, 9, 10,   2 (N)

 

Input Connection - AM50T
Input Connection Pin No.
100-300 Vdc or 230 Vac 1Ø 1 (+)(H), 14 (-)(N)
115 Vac 1Ø 47-440 Hz 1 (H), 2 (N)
115/230 Vac 3Ødelta.gif (145 bytes) 47-440 Hz 1, 14, 15
115 Vac 3ØY 47-440 Hz 1, 14, 15,   2 (N)


Click here for a larger version of this graphic.

 

Model Numbering System
Model Series Total Output Power Number of Outputs clear_dot.gif (43 bytes) Main Output Voltage clear_dot.gif (43 bytes) Aux. Output Voltage clear_dot.gif (43 bytes) Header Type Input
Variation
clear_dot.gif (43 bytes) Options
AM 50 T / 5 / 12 - A (U) - 883

 

Options
-883 Option: Unit undergoes environmental screening based upon the parameters outlined in MIL-STD-883 and NAVMAT 4855-1. The screening consists of :
1.) Stablization Bake: +125oC for 24 hours per MIl-STD-883, M1108 Condition B.
2.) Temperature Cycling (non-operational): 10 cycles min., at -55oC to +125oC, 36 minute transition with 1 hour dwell at each temperature extreme. Procedure reference MIl-STD-883, M1010, Condition B and NAVMAT P4855-1.
3.) Long Term Operational Burn In: 160 hours of powered operation under load. Modules are continuously cycled from +85oC to thermal shut down point (+105oC) during the 160 hours.
Environmental Stress Screening: Environmental Stress Screening (ESS) including random vibration and thermal cycling per the NAVMAT guidelines is available.  Consult factory for details.
Ruggedized: COTS readily available components are utilized. Contact factory for details.
-ER Option: Provides increased reliability by using higher levels of military grade components.  (Not recommended for new designs.)