AM Series (AM100S)
100 Watt Single Output Power Supply

Features
Customer selectable, Multi-Inputs.
Wireless submodular construction for high reliablity.
Short circuit protection standard.

 

Specifications
Input: 103 to 127 Vac, 47-440 Hz, single phase or,
206 to 254 Vac, 47-440 Hz, single phase or,
200 to 300 Vdc.
See Input connection/pin no.
Efficiency: 65% minimum. Typically (full load, room ambient) 75%
Line Regulation: 0.1% or 10 mV, whichever is greater.
Load Regulation: 0.1% or 10 mV, whichever is greater.
Pard (Noise and Ripple): 25mV rms, 100mV P-P for 5 Vda output and 50 mV rms, 200 mV P-P for other voltages; measured at 25 MHz bandwidth over temperature range.
Isolation Voltage: 1000 Vdc, input to output; 1000 Vdc, input to case; 200 Vdc, output to case.
Insulation Resistance: 50 Mohms between input and output, input and case, output and case, when measured at 50 Vdc.
Temperature Range: Operating: -55ºC to +100ºC maximum, at center of the baseplate. Storage: -55ºC to +125ºC, ambient.
Temperature Coefficient: 0.01% / °C maximum over entire temp range.
Input Transient Protection: Unit will not be damaged or exhibit degradation of performance when subjected to input transients in accordance with MIL-STD-704A, MIL-STD-704D and MIL-STD-1399, as applicable to corresponding input configurations.
Load Transient Recovery: Output voltage returns to regulation limits within 0.5 milliseconds after 50% change in load current.
Load Transient Overshoot: 0.5V from nominal voltage set point.
Short Circuit Protection: Completely protected against a short circuit of any duration. Output automatically restores to normal when overload is removed.
Current Limiting: Standard.
Remote Sensing: Regulator monitors voltage directly at the load using extra "sensing" leads and compensates for a dc voltage drop up to .5 volt in the load leads.  Sense pins must be tied local (at connector) or remote (at load) for proper operation.
Remote Inhibit: Provides for remote turn on/off with TTL logic signal. Application of TTL Signal (logic 1) will inhibit the outputs.   10mA required current (@5 Vdc).
EMI: Units were designed and tested to the requirement of MIL-STD-461B, Class A1B, for generation of and susceptibility to radiated and conducted interference. For further details and reports, consult your nearest sales office.
Switching Frequency: 160 to 200 kHz fixed.
Reliability: MTBF is calculated per MIL-HDBK-217E at 50ºC baseplate temperature with maximum operating input voltage and maximum rated output power. The MTBF for AM50S at ground benign environment is 160,300 hours. With -ER option, MTBF was calculated to be 240,000 hours at ground benign and 25,000 for naval sheltered.
Environment: Units meet MIL-STD-810D, altitude, shock acceleration, vibration and MIL-S-901C high-impact shock requirements. Please consult factory for more information.
Hook Up: Via D-Subminiature connectors, M24308/24 type.


Single Output
clear_dot.gif (43 bytes) Nominal
Output
Voltage
Output Current (Amps) Wt. (Oz.) Size (inches)
AM100S/5-A 5 20.0 28 4.25 x 6.00 x .85
AM100S/5.2-A 5.2 19.23 28 4.25 x 6.00 x .85
AM100S/12-A 12 8.33 28 4.25 x 6.00 x .85
AM100S/15-A 15 6.67 28 4.25 x 6.00 x .85
AM100S/24-A 24 4.17 28 4.25 x 6.00 x .85
AM100S/28-A 28 3.57 28 4.25 x 6.00 x .85
Set point accuracy: 50mV or 0.5% whichever is greater

Input Connection
Input Connection Pin No.
200-300 Vdc or 230 Vac 1 Ø 1, 2(+)(H)   3, 16(-)(N)
115 Vac 1 Ø 47-440Hz 14, 15(H)   3, 16(N)

Click here for a larger version of this graphic.

Model Numbering System
Model Series Total Output Power Number of Outputs clear_dot.gif (43 bytes) Main Output Voltage clear_dot.gif (43 bytes) Aux. Output Voltage clear_dot.gif (43 bytes) Header Type Input
Variation
clear_dot.gif (43 bytes) Options
AM 100 S / 5 / 12 - A (U) - 883

 

Options
-883 Option: Unit undergoes environmental screening based upon the parameters outlined in MIL-STD-883 and NAVMAT 4855-1. The screening consists of :
1.) Stablization Bake: +125oC for 24 hours per MIl-STD-883, M1108 Condition B.
2.) Temperature Cycling (non-operational): 10 cycles min., at -55oC to +125oC, 36 minute transition with 1 hour dwell at each temperature extreme. Procedure reference MIl-STD-883, M1010, Condition B and NAVMAT P4855-1.
3.) Long Term Operational Burn In: 160 hours of powered operation under load. Modules are continuously cycled from +85oC to thermal shut down point (+105oC) during the 160 hours.
Environmental Stress Screening: Environmental Stress Screening (ESS) including random vibration and thermal cycling per the NAVMAT guidelines is available.  Consult factory for details.
Ruggedized: COTS readily available components are utilized. Contact factory for details.
-ER Option: Provides increased reliability by using higher levels of military grade components.  (Not recommended for new designs.)