TEST REPORT ON
FIVE (5) POWER SUPPLIES
ONE (1) PART NUMBER SM200D
TWO (2) PART NUMBER SM200S
TWO (2) PART NUMBER SMH100S
FOR
MARTEK POWER ABBOTT ELECTRONICS

TEST REPORT NO. TR36962

JULY 6, 1995


 


Written by: Debra H. Osterberg, Technical Writer Date: 7/6/95
Approved by: A.S. Brockamp, Quality Assurance Manager Date: 7/7/95
1.0 PURPOSE
The purpose of this test report is to present the procedures used and the results obtained during the testing of five (5) Power Supplies, one (1) part number SM200D, s/n 1600051, two (2) part number SM200S, s/n 1200463, 1200907, and two (2) part number SMH100S, s/n 5400065 and 5400093 Testing was conducted in accordance with 2.1 thru 2.3 below.
2.0 REFERENCES
2.1 Martek Power Abbott Electronics Purchase Order Number 86548
2.2 MIL-STD-810E
2.3 MIL-S-901C
3.0 MANUFACTURER
MARTEK POWER ABBOTT ELECTRONICS
2727 S. La Cienega Boulevard
Los Angeles, CA  90016
4.0 SUMMARY
ThePower Supplies, herein after referred to as the "specimens", were subjected to the tests of 6.0 herein, in accordance with 2.1 thru 2.3 above, as follows:

TEST MATRIX

TEST TITLE

REFERENCE 2.2
METHOD

REPORT
PARAGRAPH

VIBRATION 514.4 6.1
HUMIDITY 507.3 6.2
TEMPERATURE/ALTITUDE 520.1 6.3
ACCELERATION 513.4 6.4
TEMPERATURE SHOCK 503.3 6.5
HIGH IMPACT SHOCK MIL-S-901C 6.6

 

Thisprogram is described in detail in section 6.0, herein.
The specimens met the requirements of the specification without exception or deviation.
Loadbanks were supplied by Abbott Electronics.
This test report represents Independent Testing Laboratories, Inc. findings and conclusions based upon the conduct of the test and procedures described herein with respect only to the particular product(s) or component(s) which were provided to Independent Testing Laboratories, Inc. by the customer for testing and evaluation proposed per written purchase orders, procedures or verbal instructions.  All findings and conclusions set forth herein are expressly limited by and are subject to the conditions, exceptions, qualifications, parameters, and limitations described and noted herein.  Independent Testing Laboratories, Inc. hereby expressly disclaims any responsibility of any nature or type whatsoever with respect to the applicability of the results set forth hereing to products or components other than the particular product(s) or component(s) which were actually physically tested by Independent Testing Laboratories, Inc. for purposes of this test report.
6.0 REQUIREMENTS, PROCEDURES AND RESULTS
MIL-STD-810E, Method 514.4, Proc. 1
6.1 VIBRATION
6.1.1 PERFORMANCE CRITERIA
The specimens shall show proper output voltage during and after this test.
6.1.2 TEST PROCEDURE
The test specimens were subjected to vibration in each of the three (3) mutually perpendicular axes (X, Y and Z) in the frequency range of 5 to 2000 Hz, one octave per minute sweeps, 0.06" d.a. from 5 to 99 Hz, 30 G from 99 to 2000 Hz, one (1) hour per axis.
6.1.3 TEST RESULTS
The specimens met the requirements of paragraph 6.1.1 above.
Datafor this test are presented herein in Appendix A.
MIL-STD-810E, Method 507.3, Proc. 1
6.2 HUMIDITY
6.2.1 PERFORMANCE CRITERIA
The specimens shall show proper output voltage after this test.
6.2.2 TEST PROCEDURE
The specimens were placed in a humidity chamber and tested in accordance with Method 507.3, Procedure 1 of Reference 2.2, herein for a period of ten (10) days.
The specimens were non-operating during the test.
6.2.3 TEST RESULTS
The specimens met the requirements of paragraph 6.2.1 above.
Datafor this test are presented herein in Appendix A.
MIL-STD-810E, Method 520.1, Proc. 3
6.3 TEMPERATURE / ALTITUDE
6.3.1 PERFORMANCE CRITERIA
The specimens shall show proper output voltage during and after this test.
 
6.3.2 TEST PROCEDURE
The specimens were subjected to Temperature / Altitude testing in accordance with Method 520.1, Procedure 3, Figure 520-1.5 of Reference 2.2, herein for 40 hours from -55°C to 71°C, 70,000 feet.
The specimens were operated during this test.
6.3.3 TEST RESULTS
The specimens met the requirements of paragraph 6.3.1 above.
Data for this test are presented herein in Appendix A.
MIL-STD-810E, Method 513.4, Proc. 3
6.4 ACCELERATION
6.4.1 PERFORMANCE CRITERIA
The specimens shall show proper output voltage after this test.
6.4.2 TEST PROCEDURE
The specimens were mounted to a flat aluminum plate and in turn mounted to the centrifuge arm. Power was applied to the specimens. A constant acceleration level of 14 G's was applied for a minimum of one (1) minute. The application of 14 G's for one (1) minute was repeated in both directions of all three (3) mutually perpendicular axes.
The specimens were non-operating during the test.
6.4.3 TEST RESULTS
The specimens met the requirements of paragraph 6.4.1 above.
Datafor this test are presented herein in Appendix A.
MIL-STD-810E, Method 503.3
6.5 TEMPERATURE SHOCK
6.5.1 PERFORMANCE CRITERIA
The specimens shall show proper output voltage during and after this test.
6.5.2 TEST PROCEDURE
The specimens were subjected to Temperature Shock in accordance with Method 503.3 of Reference 2.2, herein at -55°C to +100°C (non-operating) one (1) hour at each extreme, 5°C per minute, three (3) cycles.
The specimens were non-operating during this test.
6.5.3 TEST RESULTS
The specimens met the requirements of paragraph 6.5.1 above.
Data forthis test are presented herein in Appendix A.
MIL-S-901C
6.6 HIGH IMPACT SHOCK
6.6.1 PERFORMANCE CRITERIA
The specimens were mounted to a flat aluminum plate and in turn mounted to the High Impact Light Weight Shock Machine and subjected to six blows as specified in MIL-S-901, Grade A, Class 1, Type A mounted, as follows:
The specimens were subjected to shock impacts from hammer drop heights of one, three, and five feet in each of three (3) directions, back, top, and bottom for a total of nine (9) impacts.
The specimens were operated at the conclusion of the test. The voltages are listed below.
VOLTAGE AFTER SHOCK:
S/N 5400065 +12.0 Vdc
S/N 5400093 +12.0 Vdc
S/N 1600051 +12.0/-12.0 Vdc
S/N 1200463 +15.0 Vdc
S/N 1200907 +5.2 Vdc
6.6.3 TEST RESULTS
The specimens met the requirements of paragraph 6.6.1 above.
Data for this test are presented herein in Appendix A.


 

[Products] [Request Info.] [Terms & Conditions]
[Warranty Information] [Engineering Department]
[EMI Reports] [Environmental Reports] [Product Search]

 

Please send site comments / suggestions to our Webmaster

Martek Power Abbott, Inc.
1111 Knox Street
Torrance, CA 90502, USA

Tel: (310) 202-8820 Fax: (310) 836-4926


© 2007 Martek Power Abbott, Inc. All Rights Reserved.
This page last updated on March 19, 2008 07:02 PM.