power.jpg (5308 bytes)    

Welcome to Martek Power Abbott.


 

Environmental Test Reports

 

TEST REPORT ON
FOUR (4) POWER SUPPLIES


P/N: NB50DM/12/15, S/N: 467066,
P/N: CB30SM/2, S/N: 468546,
P/N: CB5SM/5, S/N:489095, AND
NB150SM/5, S/N: PROTO #3

FOR
MARTEK POWER ABBOTT

TEST REPORT NO. R25983A

Jan  16, 2004


Prepared by:
GARWOOD LABORATORIES, INC.
7829 Industry Avenue
Pico Rivera, CA 90660
Tel: 562-949-2727

 


Prepared by: R.M. "Rick" Clemens,
Technical Writer
Date: 1/16/04
Approved by: William Flower,
Quality Assurance Manager
Date: 1/16/04
Approved by: Vic Vergilio,
Laboratory Manager
Date: 1/16/04
 
 
 
1.0 PURPOSE

1.1 

  The purpose of this test report is to present procedures employed and the results obtained while conducting the Environmental Tests of Vibration, Humidity, Temperature/ Humidity/ Altitude, Acceleration, Temperature Shock, and High Impact Shock, four (4) Power Supplies, P/N: NW50DM/12/15, S/n: 467066, P/N: CB30SM/2, S/n: 468546, P/N: CB5SM/5, S/N: 489095, and P/N: NB150SM/5, S/N: Proto #3, submitted by Martek Power.

1.2

  The Environmental Tests as described in this report were performed in accordance with the references in Para. 2.0 of this report.

 
2.0 REFERENCES
2.1 5739 Martek Power Purchase Order
2.2 S.O.W. Martek Power Statement of Work, Environmental Tests
2.3 MIL-STD-810F Department of Defense Test Method Standard for Environmental Engineering Considerations and laboratory Tests
2.4 ISO 10012-1 Quality Assurance Requirements for Measuring Equipment
2.3 ANSI/NCSL Z540-1-1994 Calibration Laboratories and Measuring and Test Equipment General Requirements

 
3.0 SUMMARY
3.1   The four (4) Power Supplies, P/N: NW50DM/12/15, S/n: 467066, P/N: CB30SM/2, S/n: 468546, P/N: CB5SM/5, S/N: 489095, and P/N: NB150SM/5, S/N: Proto #3, were subjected to and completed the specified Environmental Test of Vibration, with no visible evidence of damage or deterioration noted due to testing
3.2 The four (4) Power Supplies were considered to have met the requirements of the specified Environmental Test as conducted by Garwood Laboratories, Inc, with conditions as noted in this report.
3.3 The four (4) Power Supplies were returned to Martek Power for further evaluation after the completion of testing

 


 

[Products] [Request Info.] [Terms & Conditions]
[Warranty Information] [Engineering Department]
[EMI Reports] [Environmental Reports] [Product Search]

 

Please send site comments / suggestions to our Webmaster

Martek Power Abbott, Inc.
1111 Knox Street
Torrance, CA 90502, USA

Tel: (310) 202-8820 Fax: (310) 836-4926


© 2007 Martek Power Abbott, Inc. All Rights Reserved.